Indian Standard Electrical Calculators

⚡ Cable Sizer (IS Standard)

Calculate sq.mm wire size and exact voltage drop for Indian standard voltages.

Sizing Analysis
Allowable Voltage Drop: -- V
Mathematically Required: -- sq.mm
IS Standard Recommended: -- sq.mm
Actual Drop at standard size: -- %

⚙️ Motor MCB/MCCB Sizer

Calculate Full Load Amps (FLA) and select the proper Indian market standard circuit breaker.

Motor Dashboard
Running Current (FLA): -- A
Starting Current (approx DOL): -- A
Standard Breaker Size MCB/MCCB -- A
Academic Electrical Calculators

⚡ Ohm's Law & Power Wheel

Enter exactly TWO known values, and the calculator will automatically solve the other two.

Calculated Circuit Profile
Voltage
-- V
Current
-- A
Resistance
-- Ω
Power
-- W

🎨 Resistor Color Decoder

Supports fully featured 4-band, 5-band, and 6-band resistors (with temp coefficient).

4-Band
5-Band
6-Band
Decoded Resistance
-- Ω
± -- %
Pro Electrical Calculators

🏭 Power Factor (kVAR) Sizer

Industrial tool to calculate the exact Capacitor Bank needed to correct power factor and save on penalties.

Capacitor Requirements
Required Correction: -- kVAr
Capacitor Line Current: -- A
✓ Installing this capacitor bank will prevent grid penalties and reduce line losses.

☀️ Solar / UPS Run-Time

Calculates exactly how long an inverter/battery bank will power a given load based on Depth of Discharge.

UPS / Battery Performance
Estimated Run-Time: -- hrs -- mins
Battery Current Draw: -- A
Usable Energy Capacity: -- Wh
Master-Electrix Planner

The Master-Electrix Planner

The Ultimate Project Wiring & Load Estimator for Freshers & Contractors

1. Sector
2. Sub-Scope
3. Load Estimation
4. Blue-Print & Wiring Guide

What type of project are you working on?

🏠

Residential

Homes, Apartments, Villas. Focuses on domestic appliances, conceal conduits, and human safety standards.

🏢

Commercial

Offices, Malls, Retail. Focuses on heavy Central ACs, massive lighting grids, and continuous loads.

🏭

Industrial & Pharma

Factories, Pharma Reactors, Heavy Machineries. Intense focus on XLPE Armoured cables, Star-Delta panels, and FLP safety.

Select the specific project scope:

Appliance & Machinery Load List

We have pre-filled standard items for this scope. Adjust the quantities as needed.

Equipment / Machine Name Unit Rating (Watts) Quantity Total (Watts)

Project Blueprint & Master Guide

Review your load calculations and official wiring & safety guidelines below.

Total Connected Load

-- kW
Requires -- connection.

Recommended DG / Transformer Size

-- kVA
(Factoring 0.8pf & 20% margin)
Ultimate Solar Array Calculator

☀️ Solar Rooftop Design Engineer

Calculate your exact solar panel requirement, roof layout, and financial savings instantly.

Monthly Bill (₹)
Monthly Units (kWh)

Average Indian default is ₹8.

Please input your electrical usage on the left.
Calculations will appear here automatically.

Pharma Industries Related

⚠️ Intrinsic Safety (IS) Loop Validator

For hazardous EX zones (Class 1 Div 1 / ATEX Zone 0)

Barrier / Power Supply

Field Device & Cable

Evaluating...
Voltage Match (Ui ≥ Uo) --
Current Match (Ii ≥ Io) --
Power Match (Pi ≥ Po) --
Capacitance (Co ≥ Ci + Cc) --
Inductance (Lo ≥ Li + Lc) --
All 5 conditions must be met for the loop to be certified Intrinsically Safe.

💡 Cleanroom IP65 Lux Layout

Fixture Specifications

UF is typically low (0.5-0.6) in cleanrooms due to flush mounting and HEPA ceiling space restrictions.
14
Teardrop / Flush Fixtures Required
52,100
Total Lumens Req.
0.50
Total Load (kW)
Ensure fixtures are sealed IP65/IP66 and positioned between the turbulent-free zones of HEPA supply diffusers to prevent airflow blockage.

🔋 Critical Process UPS Sizer

Avoid batch loss by sizing backup for Bioreactors, Chillers, and AHUs.

208 kVA
Minimum UPS Rating
104 Ah
Minimum Battery Bank Capacity
At selected DC Bus Voltage
Sufficient to safely bridge the gap before diesel generators parallel and accept load.

⚡ VFD Reflected Wave Calculator

Predicts peak voltage spikes at motor terminals due to long cables on AHUs.

1,300 V
Peak Voltage at Motor
Loading...
Assumes pulse velocity ~500 ft/µs. Spikes breaking motor insulation class limits require dV/dt filters or VFD-grade cables.

🚜 Motor Startup Voltage Drop

Ensure large pharma chillers & centrifuges don't trip facility power on startup.

1,632 A
Inrush Current
6.2 %
Voltage Drop on Grid
⚠️ WARNING: Flicker may be noticeable.

🛑 Conduit Fill Calculator

Calculates the legal 40% fill limit for multiple cables in standard PVC piping.

25 mm
Minimum Required PVC Pipe
34 %
Actual Fill Ratio
Max safe fill ratio is universally recognized as 40% for >2 wires to avoid thermal damage.

⚡ Transformer & Substation Sizer

Essential for panel builders sizing main ACB/MCCB breakers.

1,391 A
Full Load Amps (FLA)
27.8 kA
Max Short-Circuit (Fault) Current
Minimum required breaker breaking capacity

🏢 Genset (DG Set) Auto-Sizer

Calculates actual Commercial backup Diesel Generator requirements.

250 kVA
Minimum Generator Rating
210 kW
Connected Load
157 kW
Peak Demand (kW)
Sized at 0.8 Power Factor + added 25% safety margin to accommodate motor start inrush.

☀️ PV String Sizer (Cold-Weather)

Prevents cold-weather voltage spikes from detonating your inverter!

20
Maximum Panels in Series String
49.9 V
Voc per Panel at Record Cold
Panels are rated at 25°C. When temps drop, voltage spikes up.

🌍 Grounding / Earthing Resistance

Verified by IEEE standard equations for vertical rod electrodes.

8.4 Ω
Calculated Rod Resistance
Loading...
Uses the formula: R = (ρ / 2πL) × [ln(4L/a) - 1]. If it fails, hammer a longer rod, use multiple rods in parallel, or treat the soil with bentonite.

🏭 Panel Builder Component Sizer

Instantly size Contactors and Relays for heavy machinery.

Estimated Full Load Amps (FLA) 55 A
STAR-DELTA Setup
Component
Min Rating
Main Contactor (58%)
32 A
Delta Contactor (58%)
32 A
Star Contactor (33%)
18 A
Thermal Overload Relay
Set at 32 A
DIRECT ON LINE (DOL) Setup
Contactor & OLR (100%)
55 A